ICM280 Goodman Furnace Control Circuit Board Product Description:
- OEM Replacement
Product Description
ICM280 Goodman Furnace Control Circuit Board FEATURES Includes flash code diagnostics. Twinning. Includes mounting hole template. Fused to protect low voltage system transformers. Adjustable blower relay. 90+ furnace option. SPECIFICATIONS Operating Temperature . .-40 to 176F Humidity Range . . 95% RH (non-condensing) Mounting . . . Plastic standoffs Electrical Ratings @ 77F (25C) Input Voltage . . . 20-30 VAC RMS 50/60 Hz Maximum Input Current @ 30 VAC 0.35 amp Relay Load Ratings Valve Relay 1.5 amp @ 30 VAC 50/60 Hz 0.6 pf Ignitor Relay . . . 5.0 amp @ 120 VAC 50/60 Hz Inducer Relay . . . 4.0 FLA-8.0 LRA @ 120 VAC Circulator Relay . . .14.5 FLA-25.0 LRA @ 120 VAC Flame Current Requirements Minimum current to insure flame detection . . . 75 uA DC Maximum current for non-detection . . . . . . . . 0.10 uA DC Maximum allowable leakage resistance . . . . . 100 M ohms
Customer Reviews
Most helpful customer reviews
2 of 2 people found the following review helpful.Goodman Furnace Control Board
By K. Weerts
This board arrived quickly and allowed me to put my furnace back into operation right away. It was the current replacement model for the failed board. Good price too!
0 of 0 people found the following review helpful.Goodman B18099-06 To ICM280 replacement furnace controller
By Daniel Pomales
I have a old GMP075-03 furnace with a B18099-06 controller board. I could not afford to pay a HVAC company $500.00 or more dollars to fix my furnace. The furnace was intermittently turning off. It took multiple attempts for the furnace to ignite. I replaced the flame sensor to no avail. I replaced the pressure switch to no avail. I tested and reset the flame rollout switches to no avail. The igniter finally failed and had to be replaced. I paid $38.00 for the pressure switch, $18.00 for the flame sensor, $60.00 for the igniter and $90.00 for the ICM280 furnace controller. I ended up spending $206.00 total to fix the furnace. The ICM280 furnace controller is a excellent replacement controller for my old Goodman Janitrol GMP075-03 furnace. It works great! Follow the instructions and you cannot go wrong. I labeled all of the wires on the old controller before I pulled them off. I cut the white jumper between pins 1 and 4 on the 9 pin connector. I wired up the 24 volt transformer connection as instructed. I connected the R, G and W thermostat wires as instructed. I turned on the gas and electricity and everything started working like new! Problem resolved!
0 of 0 people found the following review helpful.furnace
By mee
The product worked well, it was fast delivery, everyhing was in order and it did a great job. I was very pleased with the condition it came in and how easy it was to hook back up.
Latest Price: See on Amazon.com!
More Info: See on Amazon.com!
See Customers Review: See on Amazon.com!